Magnetic Track Lighting

Review the current magnetic lighting modules as part of a matched track system. Compare recorded power, voltage, dimensions and optical options; verify the rail, connector and power supply together before ordering.

series
10
source configurations
27

Product range

10 series

Show remaining products (2)

Choose by the actual configuration

Each row is one catalog configuration. Options shown on different rows are not automatically interchangeable.

Series / modelPowerVoltageBeam angleDimensionsInstallationDriver
Magnetic Track Light S07-R00410 W48 V120°L300*W22*H26Lifud
Magnetic Track Light S07-R00420 W48 V120°L600*W22*H26Lifud
Magnetic Track Light S07-R00430 W48 V120°L900*W22*H26Lifud
Magnetic Track Light S07-R00440 W48 V120°L1200*W22*H26Lifud
Magnetic Track Light S07-R0086 W48 V24°L112*W22*H26Lifud
Magnetic Track Light S07-R00812 W48 V24°L220*W22*H26Lifud
Magnetic Track Light S07-R00818 W48 V24°L328*W22*H26Lifud
Magnetic Track Light S07-R00824 W48 V24°L435*W22*H26Lifud
Magnetic Track Light S07-R0126 W48 V24°L112*W22*H106Lifud
Magnetic Track Light S07-R01212 W48 V24°L220*W22*H106Lifud
Magnetic Track Light S07-R0147 W48 V24°Φ45*H100Lifud
Magnetic Track Light S07-R01412 W48 V24°Φ55*H115Lifud
Magnetic Track Light S07-R01415 W48 V24°Φ55*H115Lifud
Magnetic Track Light S07-R01424 W48 V24°Φ65*H35Lifud
Magnetic Track Light S07-R0187 W48 V24°Φ30*H420PendantLifud
Magnetic Track Light S07-R03512 W48 V120°L412*W16*H18Lifud
Magnetic Track Light S07-R03520 W48 V120°L712*W16*H18Lifud
Magnetic Track Light S07-R03530 W48 V120°L962*W16*H18Lifud
Magnetic Track Light S07-R0386 W48 V24°L231*W16*H18Lifud
Magnetic Track Light S07-R03812 W48 V24°L345*W16*H18Lifud
Magnetic Track Light S07-R03818 W48 V24°L459*W16*H18Lifud
Magnetic Track Light S07-R0416 W48 V24°L112*W16*H136Lifud
Magnetic Track Light S07-R04112 W48 V24°L225*W16*H136Lifud
Magnetic Track Light S07-R0437 W48 V24°Φ45*H100Lifud
Magnetic Track Light S07-R04312 W48 V24°Φ55*H115Lifud
Magnetic Track Light S07-R04320 W48 V24°Φ65*H35Lifud
Magnetic Track Light S07-R0467 W48 V24°Φ30*H420PendantLifud

Selection guide

Choose the lighting task before the module: focused display lighting and broader distribution need different optics. A magnetic attachment does not establish electrical or mechanical compatibility by itself.

Build the selection around the lighting task and the complete rail system. The current range includes modules with different body formats, dimensions and distributions; a long diffuse module and a focused module should not be treated as equivalent because both attach magnetically. Compare the actual source rows for power, voltage, size and beam before placing modules in a layout. The table preserves the configuration boundaries, while the individual series page shows shared specifications and model differences. Keep the chosen module, matching rail, feed arrangement and power supply identifiable in the quotation instead of using a generic magnetic-track description for the whole order.

Installation & application planning

Confirm the specified operating voltage and compatible track interface. Plan the power supply using the selected modules; do not assume universal rails or unlisted dimming protocols.

Plan rail positions in relation to the displays and viewing directions, then identify the modules that carry each lighting task. A flexible retail arrangement still needs a confirmed electrical and mechanical system. Check the recorded installation format, available ceiling space and the specified supply voltage; coordinate feeds, corners and connection details using the matching component information. A module photograph does not confirm the rail’s mounting hardware or a hidden connector design. For a showroom revision, record which modules are being moved or added and review the supply arrangement again rather than assuming every combination is supported by an existing rail.

  • Retail presentation
  • Showrooms
  • Flexible display layouts

Technical questions

Are all magnetic tracks interchangeable?

No universal compatibility is assumed. Check the actual rail profile, contact arrangement, connector and operating voltage as one system before pairing components.

Can the dimming protocol be inferred from the track?

No. Use the recorded driver and control configuration of the exact module. Do not infer DALI or another protocol from the product shape or magnetic connection.

Should I assume every magnetic module uses the same voltage?

Use the voltage on the exact product record and confirm it with the matching track and power equipment. A category name or a similar magnetic adapter is not a voltage specification. Where this catalog lists 48 V, keep that value tied to the relevant module rather than turning it into a claim about every possible rail. The complete system selection must resolve the supply and interface before modules are combined or added to an installation.

How do focused and diffuse modules differ in selection?

Start with whether the task is to highlight a particular display or provide a broader luminous element. Compare the distribution and beam recorded for each module, not merely its length or power. For example, the current records include different beam descriptions across S07 families; their optical roles should remain distinct. A room plan may use more than one module type, but their combined effect still needs assessment for the actual mounting positions and targets.

Can the installed system accept extra modules without review?

An additional module changes the selected load and may introduce a different interface or control requirement. Record the existing equipment, the proposed modules and their specified power, then confirm the matching supply and rail arrangement. Do not infer spare capacity from the physical space left on the rail. The catalog comparison supports component identification; it does not replace the system documentation needed to approve an extension in a real shop or showroom.

What belongs in a magnetic-track quotation request?

Provide the chosen module links and configurations, quantities, planned rail layout, mounting format and available supply information. Specify the desired catalog light colour and optical option for each module. Include any required control function explicitly rather than assuming it from the driver brand. Mark corners, feeds and display positions on the drawing so the inquiry concerns a coordinated system instead of a collection of parts that merely share a magnetic appearance.

Plan your lighting specification

Send the selected series, configuration, quantities and project requirements. Keep dimensions, voltage and optical options tied to the exact configuration.

Request a quote ↗